REINFORCED CONCRETE STEEL FRAME COMBINATIONS

SEPARATING
WALLS
SEPARATING FLOORS
E-FC-2 E-FC-10 E-FC-18 E-FS-1 E-FS-2 E-FS-3
E-WS-1 W 1 W W 1 W 1
E-WS-2 W W W W
E-WS-3 W W W W W W
E-WS-4 W 1 W W 1 W 1
E-WS-5 W W W
E-WS-6 N/A - FOR HOUSES ONLY

 

KEY
W Only the separating wall requires pre-completion sound testing.
1 Lightweight steel and timber frame walls may be constructed above in-situ poured concrete floors. The lightweight walls built directly off the concrete floors may be registerd as Robust Details provided:
  • they meet all other requirements of the Robust Details, including flanking constructions
  • the principles of the raft foundation junction are followed. As such, the concrete of the floor must have a mass of 365 kg/m2 (min), and a floating floor treatment must be provided.
Walls constructed to the soffit of in-situ poured concrete floors can not be registered as Robust Details and may be subject to pre-completion sound testing.

Decibel Ratings
E-xx-nn Building Regs
  Invalid Combination
Building Regs Combination